Sterile syringe filters made of PES or PVDF

Nest

84,63£

  • Professional membranes made of PES or PVDV placed in a medical-quality PP housing
  • Gamma sterilization
  • Sterile, Free from DNase and RNase and human DNA, pyrogens and PCR inhibitors, endotoxins, ATP, non-mutagenic
  • Made of non-toxic, high-strength polypropylene
  • Individually packed
  • Available variant: pore diameter 0.22/filter diameter 30mm
  • Package size: 100x1pcs/100pcs.
  • Filtration of aqueous solutions, buffers and media, high protein recovery>98,5
  • High efficiency sterile filtration, LRV
  • Larger filtering area: 4,9cm2
  • Low protein binding
  • High throughput and high flow rate
  • Proper design ensures efficient use
  • Placed into bags by machine, they remain completely intact during production and packaging
  • High protection against cross-contamination
  • Full automation of production and clean room conditions
  • Sterile, non-pyrogenic, free of DNase and RNase
  • Certified RNase-, DNase- and Pyrogen free
  • Medical device for In Vitro diagnostics in accordance with Regulation 2017/746 (hereinafter: IVDR)

Download the PDF data sheet

More information about the product

ORDER - SELECTED VARIANTS

PictureSKUMembrane typePore ​​sizeSizePacking typeSterilepcs/packPriceQuantityMagazineCart
SKU: 331001Membrane type: PVDFPore ​​size: 0,22umSize: 30 mmPacking type: individuallySterile: Roofpcs/pack: 100x1pcs/100pcsPrice: 84,63£
Warehouse: In stock
SKU: 331011Membrane type: PES disciplinePore ​​size: 0,22umSize: 30 mmPacking type: individuallySterile: Roofpcs/pack: 100x1pcs/100pcsPrice: 84,63£
Warehouse: In stock

Nest Scientific Biotechnology – advanced syringe filters

Sterile syringe filters made of PES (polyethersulfone) or PVDV (polyvinylidene fluoride) offered by the renowned brand Nest Scientific Biotechnology are an irreplaceable tool in the field of laboratory filtration processes. These advanced filters are designed to deliver the highest quality performance and precision when separating substances in both research and industrial laboratories.

Reliable resistance and durability

The materials from which sterile syringe filters are made, i.e. PES and PVDF, are well known for their exceptional chemical resistance and physical durability. Polyethersulfone (PES) is characterized by excellent thermal and chemical stability, which allows the filtration of even aggressive substances without the risk of degradation of the filter material. In turn, polyvinylidene fluoride (PVDF) is exceptionally resistant to organic solvents and aggressive chemicals, which is crucial when filtering samples with complex chemical composition.

Advanced production technology

Filtration using our syringe filters is not only efficient, but also precise, which is of great importance in the field of scientific research. A properly selected filter membrane allows for effective retention of particles, pollutants and microorganisms.

The Nest Scientific Biotechnology brand is famous for the innovation and quality of its products, and Sterile Syringe Filters with PES or PVDV are no exception. Using advanced manufacturing technologies and rigorous quality control processes, these filters are an indispensable tool in the hands of researchers and scientists, helping them achieve precise and repeatable results in their experiments and analyses.

FEATURES

  • Exceptional durability and resistance: The syringe filter housing is made of high-quality medical-grade polypropylene, which is one-time injection molded. This guarantees not only durability, but also resistance to high pressure, which allows safe operation even in demanding conditions. Excellent filtration efficiency: These filters offer high sterile filtration efficiency, achieving a microorganism reduction level (LRV) of level 7. This means that they are effective in eliminating 99,99999% of microorganisms, which is extremely important in laboratory applications.
  • Larger Filter Area: Complemented with a generous 4,9 cm² filter area, the filter provides efficiency and effectiveness, allowing more samples to pass through the filter in less time.
  • Variety of Membranes: Filters use a variety of membrane materials such as PES and PVDF. This allows you to tailor your membrane selection to your specific filtration needs, increasing flexibility and precision in the process.
  • Low Protein Binding: These filters are designed to minimize protein binding, which is crucial in many laboratory applications to ensure accuracy and repeatability of results.
  • High throughput and flow rate: Thanks to their design and advanced materials, these filters are characterized by high throughput and flow rate. This allows for quick and efficient filtration processes without loss of quality.
  • Reliable packaging: Each filter is placed in a separate, sterile paper-plastic packaging that is easy to open. This ensures that the filters remain sterile and ready for use at any time.
  • Free of DNA/RNA enzymes and pyrogens: These filters are free of DNA/RNA enzymes and pyrogens, which is important in applications where the presence of these substances cannot be tolerated to ensure sample purity and uninterrupted results.
  • Hydrophilic PES
    Low protein adsorption, high flow rate, wide pH range, high chemical compatibility, good heat resistance
    For general media and aqueous solutions, polar or medium polar solvents, neutral aqueous solutions.
    Should not be used for chloroform, esters, amides and strong acids or strong bases.
  • PVDF Hydrophilic
    Wide practicability, good oxidation resistance and heat resistance
    Can be used for aqueous solutions and most solvents, including strong non-polar solvents. Perfect for HPLC and GC preparations
    Should not be used for strong acids and bases

RANGES

  • Shelf life: 3 years from the date of manufacture (make sure the packaging is in good condition)
  • Connection: F luer connector and M luer connector
  • Maximum working pressure: 87 psi
  • Maximum working temperature: 90 ° C

USAGE

  • Precise Filtration: Syringe filters made of PES or PVDF allow for accurate and effective filtration of samples and solutions. Thanks to their uniform pore structure, they ensure high efficiency in retaining particles of various sizes.
  • Sample Preparation: Filtration is a key step in preparing samples for analysis. Nest Scientific Biotechnology laboratory filters guarantee the removal of impurities, sediments and bacteria, which is extremely important in the case of biological or chemical samples.
  • Cell Cultures: In the field of biotechnology, PES or PVDF filters are used to prepare purified cell culture media. This avoids contamination and maintains optimal cell growth conditions.
  • HPLC and Mass Spectrometry: Syringe filters are an important element in preparing samples for analysis by high-performance liquid chromatography (HPLC) and mass spectrometry. They remove impurities, which translates into precise and undisturbed analysis results.
  • Filtration of Chemical Solutions: PES and PVDF filters are perfect for filtering various types of chemical solutions, eliminating unwanted contaminants and sediments. They are ideal for use in chemical analyzes and preparing solutions for reactions.
  • Molecular Biology: In molecular biology research laboratories, sterile syringe filters are used to purify reagents, enzymes and solutions before PCR or DNA sequencing.
  • Water Sample Filtration: PES and PVDF filters can be used to filter water samples to retain microorganisms and contaminants, which is important in water quality monitoring and environmental research.
  • Filtration of Pharmaceutical Formulations: In the pharmaceutical industry, syringe filters are used to purify and prepare formulas of drugs and active substances for qualitative and quantitative tests.
  • Clinical Trials: PES and PVDF filters are used in the process of preparing clinical samples for analysis. They remove contaminants, which translates into accurate and undistorted clinical test results.
  • Equipment Protection: Syringe filters protect expensive and delicate laboratory equipment, such as chromatographs and spectrometers, from contamination and damage, contributing to a longer equipment life.

CERTIFICATES

  • Manufactured in accordance with EN ISO 20417:2021, EN ISO 15223-1:2016, EN ISO 18113-1:2011, EN ISO 14971:2019
  • The in vitro diagnostic medical device complies with Regulation 2017/746 (hereinafter: IVDR)

STERILIZATION

  • Sterile: YES
  • E-beam sterilization, SAL=10-6. The product was irradiated and released dosimetrically based on ANSI/AAMI/ISO 11137
  • Each production lot is sampled and tested according to standard operating procedures. Appearance Inspection: Qualified. Leak test: qualified. Pipette Fit Test: Qualified. Packaging Inspection: Qualified.

TECHNICAL DRAWING

RECOMMENDATIONS

  • When working with chromatographic samples, avoid introducing other contaminants during the filtration process.
  • Do not use a syringe with a capacity smaller than 10 cc, as this may cause excessive pressure in the injection tube, resulting in diaphragm damage or personal injury.
  • For single use only
  • Discard the initial small amount of filtrate, the volume of which is close to the volume of the filter.